Red Hat warns high-density OpenShift UDNs can lose egress even on 5.0 GA
The failure affects primary user-defined networks at scale; Red Hat says the 5.0 fix is partial and gateway-only probes can miss it.
Red Hat has warned that OpenShift clusters with many primary user-defined networks can intermittently lose outbound connectivity, including on OpenShift 5.0.0 GA. The company’s verified knowledgebase solution, updated Nov. 15, identifies the trigger as the Open vSwitch 4,096-resubmit limit in clusters running 50 or more primary UDNs.
What fails
The issue affects OpenShift Container Platform 4.18 and later when OVN-Kubernetes is used with many primary ClusterUserDefinedNetworks or UserDefinedNetworks. Red Hat lists intermittent SSH or RDP drops to virtual machines, LDAP or OAuth login failures, and outbound connections from UDN pods timing out. The default pod network remains unaffected, according to the solution.
That distinction matters operationally: an otherwise healthy cluster can show failures only inside the tenant-style primary networks. Red Hat also says Layer 2 CUDNs are the supported scale path, while Layer 3 UDNs are not the supported option for high density.
The 5.0 fix does not close the case
OpenShift 5.0.0 GA includes OCPBUGS-85627, delivered through an OpenShift OVN-Kubernetes downstream merge. That pull request merged Aug. 11 after CI scale verification and included the change titled “Fix UDN masquerade ARP storm on external network.”
Red Hat now describes that fix as partial. It protects the default network and destinations for which a MAC binding already exists, but a subset of CUDN pods can still lose egress to a new external IP until the CUDN gateway router learns the destination’s MAC binding.
In Red Hat’s 110-Layer-2-CUDN testing, realistic egress failed for four of 110 pods on vSphere and five of 110 on AWS. A synthetic ARP storm expanded the affected set to 48 pods on vSphere and 54 on AWS. In each case, the failures matched a missing MAC binding on the pod’s node, while default-network controls continued to pass.
What platform teams should check
Teams operating dozens of primary UDNs should not treat an upgrade to 5.0 as proof that this failure mode is gone. Red Hat specifically cautions that readiness probes testing only the UDN gateway can remain green while access to a new external IP fails.
The practical check is therefore narrower and more demanding: inventory clusters approaching the 50-primary-UDN range and test outbound connectivity from UDN workloads to external destinations that do not already have a learned MAC binding. The public portion of Red Hat’s solution documents the symptoms and affected environments; its full remediation guidance is available to subscribers.
sources
comments · 0